What are HV and UHV conditions?

  • HV pressure ranges are those between 10 x 10-3 and 10 x 10-7 mbar. 
  • UHV pressure ranges are those between 10 x 10-7 and 10 x 10-12 mbar.

As with all vacuum systems, the established standards, rules, and protocols that govern vacuum factors and matters must be frequently re-examined and re-engineered. 

Users should routinely:

  • Check vacuum levels
  • Review the pump setup
  • Perform safety checks
  • Evaluate measurement methods
  • Undergo leak detection processes

PHOENIX Cart

Download our e-book "Fundamentals of leak detection"

Discover leak detection essentials and techniques

Download

Loading...

Applications

HV applications include:

UHV applications include:

Related: Find out how aerospace engineers simulate space conditions on Earth in our blog post: Vacuum Technology for Space Simulation Chambers.

uhv-blog-image-6

Factors to consider when creating HV and UVH conditions

Efficiency considerations

Users should carry out a careful assessment of design, materials, and the condition of the vacuum system to identify problem areas. HV and UHV vacuum system efficiency can be improved by following several best practices:

  • Minimize the chamber’s internal surface area.
  • Weld only from the inside.
  • Use low desorption/outgassing rates. 
  • Pre-treat materials — for example, undergo electro-polishing.
  • Check for internal gaps or trapped volumes, like tapped blind holes. 
  • Use metallic seals.
  • Reduce the number of seals and feed-throughs. 

Outgassing

Outgassing is the process of releasing gas that was dissolved, trapped or absorbed in some material. To create and maintain clean HV and UHV vacuum environments, users must carefully monitor outgassing.  

Outgassing typically occurs when materials not usually considered absorbent, release enough molecules to interfere with industrial or scientific vacuum processes. Common sources of outgassing include:

  • Moisture
  • Sealants 
  • Lubricants
  • Adhesives
  • Metal impurities
  • Glass cracks 

Cleaning surfaces, heating individual components, or performing a bake-out can drive off volatiles. 

Gas load

In HV and UHV conditions, outgassing and degassing levels must be kept as low as possible. 

Minimizing effective surfaces reduces the impact of outgassing. The higher the surface area, the greater the outgassing and the higher the system pressure. 

How do I know my operating conditions?

A residual gas analyzer (RGA) is a small quadrupole mass spectrometer, typically designed for environment analysis, process control, and contamination monitoring in vacuum systems. RGA's can monitor the quality of the vacuum by detecting (and measuring) minute traces of impurities in a low-pressure gaseous environment.  
 
RGA's are usually mounted directly onto, and into, the vacuum chamber. RGAs perform various functions which would be difficult to obtain by other methods, including: the analysis of various gas-phase reactions, monitoring changes that occur in any gas environment, detecting vacuum leaks, and checking mass flow controllers. 
 

Related: Residual Gas Analyzer or Leak Detector — which one is right for the job? Get the answer in our blog post,  When To Use An RGA.

Pump selection considerations

There are many pump types capable of producing HV and UHV vacuum pressure, and most applications require multiple pumps working together. However, pairing different types of vacuum pumps to optimize performance is not always a simple matter. 

Several factors impact the choice of pumps, such as:

  • Noise and vibrations
  • Initial and ongoing costs
  • Contamination tolerance
  • Footprint
  • Maintenance requirements
  • Shock resilience 

Related: Did you know that high noise levels can leave your team susceptible to hazards? Check out this blog post for 5 Quick Facts About Noise Pollution in Your Lab, and solutions that keep your team safe!

Pump options

Fore Pumps options include:

Main secondary pump options capable of HV and UHV levels include: 

These pumps produce vacuum conditions by rapidly evacuating, capturing, or tying up gas molecules.

LeyboldChart

Understanding pump types

Each pump type has unique advantages and disadvantages, which adds complexity to the selection process.

For example, turbomolecular pumps advantages include:

  • Easy,  kinetic operation
  • Low maintenance
  • Hydrocarbon-free operation

Disadvantages include:

  • Vibration-generating moving parts
  • Reduced pumping speed for light gases
  • Sensitivity to mechanical shock
  • Particulate contamination

Buyers should undergo a similar comparison process for each pump type to reach an informed decision. 

Summary

When creating HV and UHV conditions, it is crucial to consider these three factors: efficiency, working condition considerations, and pump selection.

If you're finding selection tough, check out our blog post,  How Do I Know Which Vacuum Pump Is Right For Me? 

With the help of resources like these, an approach that focuses on the key elements of working condition considerations, efficiency and pump selection will keep you on the path to delivering optimum performance and reliable HV and UHV conditions.

And if you've got questions, reach out to the Leybold team! We're always happy to hear from you and can help with all your HV and UHV needs. 

고진공, 초고진공, 극고진공: 기본

e-Book을 다운로드하여 고진공, 초고진공 또는 극고진공을 달성하고 작업하는 것과 관련된 과제와 고려해야 할 사항에 대해 알아보십시오.

문서 다운로드를 보여 주는 개념 아이콘

By submitting this request, Leybold will be able to contact you through the collected information. More information can be found in our privacy policy.
Leybold employee

Let's talk

We focus on customer proximity. Contact us for all your questions.

Contact us

Loading...