Rugged vacuum pumps for industrial applications

LEYVAC dry screw vacuum pumps are a class of industrial vacuum pumps based on the screw principle. The LEYVAC series from Leybold is especially developed for the process industry, food and process applications, coating and display applications. They can simply be assembled by adapters to various vacuum systems, particularly the well-proven RUVAC WH700 and WS(U) and WA(U) series.

User advantages

No oil contact to process gases 

High pumping speed for air and H2 already at high pressures

Hermetically tight

Robust and durable design

One motor solution

Easy and modular

Features at a glance

LEYVAC dry vacuum pumps provide optimized:

  • System uptime
    • Robust design based on the proven RUVAC and DRYVAC technology
    • Effective cooling system
    • Thermal switch protection
    • Tolerant to pressure shocks
    • Long intervals for bearing exchange
  • Process safety
    • Designed for harsh applications

  • Excellent performance data High pumping speed
    • from atmosphere to process pressure
    • for light gases n Low noise and low heat emission

  • Price-to-performance ratio
    • Low investment costs
    • small, price optimized pumping systems
LEYVAC LV 80
Technical Data
Technical data   LV 80 LV 80 C
LV 140 LV 140 C
Nominal pumping speed without gas ballast at 50/60 Hz m3/h 80 / 96 80 / 96 125 / 145 125 / 145
Ultimate pressure with seal and rotor purge mbar 1 x 10-2 1 x 10-2 1 x 10-2 1 x 10-2
Power consumption at ultimate pressure at 50/60 Hz kW 2.9 / 3.2 2.9 / 3.2 3.9 / 4.3 3.9 / 4.3
Weight, approx. kg 280 300 300 320
Noise level  dB(A) < 65 < 65 < 65 < 65
Intake connection DN 63 ISO-K 63 ISO-K 63 ISO-K 63 ISO-K
Exhaust side connection DN 40 ISO-KF 40 ISO-KF 40 ISO-KF 40 ISO-KF
Mains voltage (+/- 10%) V 200 - 460 200 - 460 200 - 460 200 - 460
Nominal power at 50/60 Hz kW 4.1 4.1 5.5 5.5
Nominal current at 50/60 Hz A 6 6 8 8
Cooling water/glycol water/glycol water/glycol water/glycol
Cooling water temperature °C  5-35  5-35  5-35  5-35
Cooling water throughput l/min 3 3 3 3
Water vapor tolerance with gas ballast 50/60 Hz mbar 20/30 20/30 125/160 125/160
Water vapor capacity with gas ballast 50/60 Hz kg/h 1.24/2.3 1.24/2.3 11.5/18.0 11.5/18.0
Permissible ambient temperature °C  5-45  5-45  5-45  5-45
Protection class EN 60529 IP 54 54 54 54
Dimensions (W x H x D)    mm 814 x 375 x 550 814 x 375 x 550 895 x 400 x 567 895 x 400 x 567
Applications
  • Process industry
  • Food and packaging 
  • Coating
  • Solar
Online Shop
Technical data   LV 80 LV 80 C
LV 140 LV 140 C
Nominal pumping speed without gas ballast at 50/60 Hz m3/h 80 / 96 80 / 96 125 / 145 125 / 145
Ultimate pressure with seal and rotor purge mbar 1 x 10-2 1 x 10-2 1 x 10-2 1 x 10-2
Power consumption at ultimate pressure at 50/60 Hz kW 2.9 / 3.2 2.9 / 3.2 3.9 / 4.3 3.9 / 4.3
Weight, approx. kg 280 300 300 320
Noise level  dB(A) < 65 < 65 < 65 < 65
Intake connection DN 63 ISO-K 63 ISO-K 63 ISO-K 63 ISO-K
Exhaust side connection DN 40 ISO-KF 40 ISO-KF 40 ISO-KF 40 ISO-KF
Mains voltage (+/- 10%) V 200 - 460 200 - 460 200 - 460 200 - 460
Nominal power at 50/60 Hz kW 4.1 4.1 5.5 5.5
Nominal current at 50/60 Hz A 6 6 8 8
Cooling water/glycol water/glycol water/glycol water/glycol
Cooling water temperature °C  5-35  5-35  5-35  5-35
Cooling water throughput l/min 3 3 3 3
Water vapor tolerance with gas ballast 50/60 Hz mbar 20/30 20/30 125/160 125/160
Water vapor capacity with gas ballast 50/60 Hz kg/h 1.24/2.3 1.24/2.3 11.5/18.0 11.5/18.0
Permissible ambient temperature °C  5-45  5-45  5-45  5-45
Protection class EN 60529 IP 54 54 54 54
Dimensions (W x H x D)    mm 814 x 375 x 550 814 x 375 x 550 895 x 400 x 567 895 x 400 x 567
  • Process industry
  • Food and packaging 
  • Coating
  • Solar
Contact Leybold