TRIVAC L Oil sealed pumps
The perfect balance of performance for various applications
The new generation Leybold TRIVAC L two-stage rotary vane vacuum pumps perfectly balance the performance, reliability and overall ownership costs of your application processes. Aircooled TRIVAC L pumps are designed to meet diffused industrial application requirements requiring stable performance and ease of operation.
The standard TRIVAC L pumps with LVO 130 mineral oil meet the industrial requirements of various applications. The TRIVAC L features an optimized design that extends the uptime of your processes via convenient and efficient onsite maintenance. Custom versions of the TRIVAC L are available for specific demands, like motors, oil options and systems.
User advantages
Product Line
Complete product line for your applications:
The TRIVAC L is available in three sizes:
- TRIVAC D 40 L
 - TRIVAC D 63 L
 - TRIVAC D 90 L
 
The Standard TRIVAC L provides four options for motor selection:
- EU/CN: Economic solution for 50Hz regions with IE3 and CE defaults
 - EU/US: Wide range version for most regions with IE3 / CE / UR / CSA / EAC defaults
 - JP/KR: EU/US: Special version for Japan / Korea / Taiwan with IE3 / CE / UR / CSA / EAC defaults, design meets Korea’s KEMCO requirements
 - Bare shaft: Pump delivered without motor for individual requirements
 
Custom-made solutions for you applications
Our TRIVAC L pump systems are combinations of fore vacuum pumps along with roots vacuum pumpsand roots vacuum pumps, which are typically used to attain a base pressure of 10-3 mbar. Multistage combinations can be customized for applications where pressures below 10-4 mbar are required. A line of standard pump systems has been developed to provide the right solution for your processes.
- RUVAC WA(U), WS(U) and WH(U) roots pumps
 - Standardized adapter versions with compact footprint
 - Customized frames (e.g.: movable or on castors)
 - Electronic controls per your specifications, including solutions with electrical cabinets
 - Peripheral accessory extensions (e.g., vacuum gauges, valves, dust filters, oil mist filters…)
 - Subsystems for integration within customers’ plants
 
- Technical information
 - Documents
 - Applications
 
Technical information
  | 
TRIVAC D 40 L  | 
TRIVAC D 63 L  | 
TRIVAC D 90 L  | 
|
Nominal pumping speed  | 
m3/h  | 
49/59  | 
67/80  | 
92/110  | 
Pumping speed  | 
m3/h  | 
42/50  | 
60/72  | 
79/95  | 
Ultimate total pressure without gas ballast  | 
mbar  | 
3×10-3  | 
||
Ultimate total pressure with gas ballast position 1  | 
mbar  | 
6×10-3  | 
||
Ultimate total pressure with gas ballast position 2  | 
mbar  | 
2×10-2  | 
||
Water vapor tolerance  | 
mbar  | 
35  | 
30  | 
25  | 
Water vapor capacity 50/60Hz  | 
g/h  | 
1090/1308  | 
1334/1601  | 
1464/1757  | 
Oil filling, min / max  | 
l  | 
3.1/4.1  | 
3.3/4.3  | 
3.6/4.6  | 
Admissible ambient temperature  | 
°C  | 
10-40  | 
||
Noise level without / with gas ballast position 1  | 
dB(A)  | 
58/60  | 
||
Motor rating power 50/60Hz (EU/US)  | 
kW  | 
1.1/1.3  | 
1.5/1.8  | 
2.2/2.6  | 
Nominal speed (EU/US)  | 
rpm  | 
1445  | 
1440  | 
1455  | 
Type of protection  | 
IP  | 
55  | 
||
Intake / exhaust connection  | 
DN  | 
40 KF  | 
||
Pump dimensions (L×W×H) (EU/US)  | 
mm  | 
717×244×352  | 
747×244×352  | 
834×244×352  | 
Net weight (EU/US)  | 
kg  | 
84  | 
101  | 
|
Net weight without motor  | 
kg  | 
59  | 
63  | 
69  | 
Documents
Applications
Charging System
- Refrigerator production
 - Air conditioner
 - Heat pump production
 - Heat pipe production
 
General Industry
- Leak detection systems
 - Insulated containers
 - LNG-Cryo tanks production
 - Purification
 - Oil degassing
 
Furnace & Metallurgy
- Industrial furnaces
 - Heat treatment
 - Welding technology
 - Metallurgical systems
 
Analytical, Research & Development
- Laboratory equipment
 - Magnetic medical equipment
 - Spectrometers and leak detectors
 
Freeze Drying
- Freeze drying of food
 - Freeze drying of pharmaceuticals
 
Special Applications
- Crystal pulling like sapphire, SiC or
 - other substrate material for Semi or Solar
 
Thin Film Coating
- Large area coating
 - Industrial coating
 
  | 
TRIVAC D 40 L  | 
TRIVAC D 63 L  | 
TRIVAC D 90 L  | 
|
Nominal pumping speed  | 
m3/h  | 
49/59  | 
67/80  | 
92/110  | 
Pumping speed  | 
m3/h  | 
42/50  | 
60/72  | 
79/95  | 
Ultimate total pressure without gas ballast  | 
mbar  | 
3×10-3  | 
||
Ultimate total pressure with gas ballast position 1  | 
mbar  | 
6×10-3  | 
||
Ultimate total pressure with gas ballast position 2  | 
mbar  | 
2×10-2  | 
||
Water vapor tolerance  | 
mbar  | 
35  | 
30  | 
25  | 
Water vapor capacity 50/60Hz  | 
g/h  | 
1090/1308  | 
1334/1601  | 
1464/1757  | 
Oil filling, min / max  | 
l  | 
3.1/4.1  | 
3.3/4.3  | 
3.6/4.6  | 
Admissible ambient temperature  | 
°C  | 
10-40  | 
||
Noise level without / with gas ballast position 1  | 
dB(A)  | 
58/60  | 
||
Motor rating power 50/60Hz (EU/US)  | 
kW  | 
1.1/1.3  | 
1.5/1.8  | 
2.2/2.6  | 
Nominal speed (EU/US)  | 
rpm  | 
1445  | 
1440  | 
1455  | 
Type of protection  | 
IP  | 
55  | 
||
Intake / exhaust connection  | 
DN  | 
40 KF  | 
||
Pump dimensions (L×W×H) (EU/US)  | 
mm  | 
717×244×352  | 
747×244×352  | 
834×244×352  | 
Net weight (EU/US)  | 
kg  | 
84  | 
101  | 
|
Net weight without motor  | 
kg  | 
59  | 
63  | 
69  | 
Charging System
- Refrigerator production
 - Air conditioner
 - Heat pump production
 - Heat pipe production
 
General Industry
- Leak detection systems
 - Insulated containers
 - LNG-Cryo tanks production
 - Purification
 - Oil degassing
 
Furnace & Metallurgy
- Industrial furnaces
 - Heat treatment
 - Welding technology
 - Metallurgical systems
 
Analytical, Research & Development
- Laboratory equipment
 - Magnetic medical equipment
 - Spectrometers and leak detectors
 
Freeze Drying
- Freeze drying of food
 - Freeze drying of pharmaceuticals
 
Special Applications
- Crystal pulling like sapphire, SiC or
 - other substrate material for Semi or Solar
 
Thin Film Coating
- Large area coating
 - Industrial coating