Choose your region to see content specific to your location
We cannot find a market for your location please choose a region
The page you are viewing is available in your preferred market.
Dry screw vacuum pumps
LEYVAC dry screw vacuum pumps are a class of industrial vacuum pumps based on the screw principle. The LEYVAC series from Leybold is especially developed for the process industry, food and process applications, coating and display applications. They can simply be assembled by adapters to various vacuum systems, particularly the well-proven RUVAC WH700 and WS(U) and WA(U) series.
No oil contact to process gases
High pumping speed for air and H2 already at high pressures
Hermetically tight
Robust and durable design
One motor solution
Easy and modular
LEYVAC dry vacuum pumps provide optimized:
Technical data | LV 80 | LV 80 C |
LV 140 | LV 140 C | |
Nominal pumping speed without gas ballast at 50/60 Hz | m3/h | 80 / 96 | 80 / 96 | 125 / 145 | 125 / 145 |
Ultimate pressure with seal and rotor purge | mbar | 1 x 10-2 | 1 x 10-2 | 1 x 10-2 | 1 x 10-2 |
Power consumption at ultimate pressure at 50/60 Hz | kW | 2.9 / 3.2 | 2.9 / 3.2 | 3.9 / 4.3 | 3.9 / 4.3 |
Weight, approx. | kg | 280 | 300 | 300 | 320 |
Noise level | dB(A) | < 65 | < 65 | < 65 | < 65 |
Intake connection | DN | 63 ISO-K | 63 ISO-K | 63 ISO-K | 63 ISO-K |
Exhaust side connection | DN | 40 ISO-KF | 40 ISO-KF | 40 ISO-KF | 40 ISO-KF |
Mains voltage (+/- 10%) | V | 200 - 460 | 200 - 460 | 200 - 460 | 200 - 460 |
Nominal power at 50/60 Hz | kW | 4.1 | 4.1 | 5.5 | 5.5 |
Nominal current at 50/60 Hz | A | 6 | 6 | 8 | 8 |
Cooling | water/glycol | water/glycol | water/glycol | water/glycol | |
Cooling water temperature | °C | 5-35 | 5-35 | 5-35 | 5-35 |
Cooling water throughput | l/min | 3 | 3 | 3 | 3 |
Water vapor tolerance with gas ballast 50/60 Hz | mbar | 20/30 | 20/30 | 125/160 | 125/160 |
Water vapor capacity with gas ballast 50/60 Hz | kg/h | 1.24/2.3 | 1.24/2.3 | 11.5/18.0 | 11.5/18.0 |
Permissible ambient temperature | °C | 5-45 | 5-45 | 5-45 | 5-45 |
Protection class EN 60529 | IP | 54 | 54 | 54 | 54 |
Dimensions (W x H x D) | mm | 814 x 375 x 550 | 814 x 375 x 550 | 895 x 400 x 567 | 895 x 400 x 567 |
Technical data | LV 80 | LV 80 C |
LV 140 | LV 140 C | |
Nominal pumping speed without gas ballast at 50/60 Hz | m3/h | 80 / 96 | 80 / 96 | 125 / 145 | 125 / 145 |
Ultimate pressure with seal and rotor purge | mbar | 1 x 10-2 | 1 x 10-2 | 1 x 10-2 | 1 x 10-2 |
Power consumption at ultimate pressure at 50/60 Hz | kW | 2.9 / 3.2 | 2.9 / 3.2 | 3.9 / 4.3 | 3.9 / 4.3 |
Weight, approx. | kg | 280 | 300 | 300 | 320 |
Noise level | dB(A) | < 65 | < 65 | < 65 | < 65 |
Intake connection | DN | 63 ISO-K | 63 ISO-K | 63 ISO-K | 63 ISO-K |
Exhaust side connection | DN | 40 ISO-KF | 40 ISO-KF | 40 ISO-KF | 40 ISO-KF |
Mains voltage (+/- 10%) | V | 200 - 460 | 200 - 460 | 200 - 460 | 200 - 460 |
Nominal power at 50/60 Hz | kW | 4.1 | 4.1 | 5.5 | 5.5 |
Nominal current at 50/60 Hz | A | 6 | 6 | 8 | 8 |
Cooling | water/glycol | water/glycol | water/glycol | water/glycol | |
Cooling water temperature | °C | 5-35 | 5-35 | 5-35 | 5-35 |
Cooling water throughput | l/min | 3 | 3 | 3 | 3 |
Water vapor tolerance with gas ballast 50/60 Hz | mbar | 20/30 | 20/30 | 125/160 | 125/160 |
Water vapor capacity with gas ballast 50/60 Hz | kg/h | 1.24/2.3 | 1.24/2.3 | 11.5/18.0 | 11.5/18.0 |
Permissible ambient temperature | °C | 5-45 | 5-45 | 5-45 | 5-45 |
Protection class EN 60529 | IP | 54 | 54 | 54 | 54 |