VARODRY VDi system
With integrated VAControl CAB for smart pump down
The VARODRY VDi are the perfect solution for smart pump down applications. These high-pumping speed versions are all equipped with our VAControl CAB for smart operation and energy saving functions. Profit from a powerful pump down to your set target pressure and benefit from significant energy savings as soon as target pressure is reached. The production configuration with purge, gas ballast and a self-draining design is perfectly suited for a wide range of applications. Intelligent software functions such as maintenance and service alerts or the set up of different user profiles guarantee best operation performance.
User advantages
Energy Saver Kit for VD 400i+
Smart Pump Down with VDi:
- More flexibility to adapt to your process needs
- Reduced process and maintenance costs
- Dry solution with higher pumping speed
- Reduced energy consumption to fulfill sustainability goals
Create more value with intelligent software functions:
- Extra energy savings with the energy saver kit
- Significant cost of ownership reductions with intelligent energy saving procedures
- Allows to switch off one VARODRY to:
- Save on energy
- Save on running time to extended maintenance intervals
- Pump alternation for equal wear
- Pressure dependent and automatically controlled by the intelligent software
- erfectly suited for all heat treatment applications
Smart control with VAControl CAB:
- Standardized products - ready-to-order!
- Intelligent pump systems with VAControl CAB
- One controller to manage all processes
- Pump data available from anywhere:
- Local, remote or cloud connectivity
- Data recording for best production quality
- Maintenance and service alerts for higher uptime
- Functions to enhance user experience:
- Starts / Stops of multiple pumps
- Pressure control
- Cloud communication via GENIUS
- Direct control via various devices
…go digital today!
The Belt Tuner
A smart tool that helps you to adjust the belt of your VARODRY & NOVADRY
Easy Maintenance
The App is always ready and can be used no matter where you are
Smart Control
The App gives further insights like detailed instructions and provides data for further improvements
Cost Effective
As part of our NOVADRY & VARODRY concept, the Belt Tuner is free of charge
- Technical Information
- Documents
- Applications
Technical Information
VARODRY VD 200i+ |
VARODRY VD 400i+ |
VARODRY VD 200i+ |
VARODRY VD 400i+ |
||||||
50 Hz |
60 Hz |
||||||||
RUVAC | WSU 501 |
WSU 1001 |
WSU 1001 |
WSU 2001 |
WSU 501 |
WSU 1001 |
WSU 1001 |
WSU 2001 |
|
Maximum pumping speed (w/o gas ballast) |
m³/h | 400 |
780 |
850 |
1660 |
480 |
910 |
1000 |
1940 |
Ultimate pressure w/o gas ballast |
mbar | 0,001 |
|||||||
Max. permissible outlet pressure (rel. to ambient) |
mbar | 200 |
|||||||
Max. permissible inlet pressure |
mbar | 1200 |
|||||||
Water vapor tolerance with gas ballast and inlet & outlet purge |
mbar | 20 |
|||||||
Water vapor capacity with gas ballast |
kg/h | 6,9 |
13,9 |
6,9 |
13,9 |
||||
Permissible ambient temperature |
°C | 0 to +40 °C |
|||||||
Purge gas consumption, inlet side |
slm | 2,5-5 |
5-10 |
2,5-5 |
5-10 |
||||
Purge gas consumption, motor side |
slm | 7,5-16 |
15-32 |
7,5-16 |
15-32 |
||||
Purge gas supply pressure |
bar (g) | 2-4 |
|||||||
Nominal motor power 50Hz / 60Hz |
kW | 9,4 |
16,5 |
9,4 |
17,5 |
||||
Dimensions (L x W H) |
mm | 1410 x 925 x 1503 |
1410 x 925 x 1772 |
1410 x 925 x 1896 |
1410 x 925 x 1503 |
1410 x 925 x 1772 |
1410 x 925 x 1896 |
||
Inlet / outlet connection |
DN63 / DN80 |
DN100 / DN80 |
DN100 / DN80 |
DN160 / DN80 |
DN63 / DN80 |
DN100 / DN80 |
DN100 / DN80 |
DN160 / DN80 |
Applications
Target applications for VDi:
- Heat Treatment
- Coating Applications
- Drying Applications
VARODRY VD 200i+ |
VARODRY VD 400i+ |
VARODRY VD 200i+ |
VARODRY VD 400i+ |
||||||
50 Hz |
60 Hz |
||||||||
RUVAC | WSU 501 |
WSU 1001 |
WSU 1001 |
WSU 2001 |
WSU 501 |
WSU 1001 |
WSU 1001 |
WSU 2001 |
|
Maximum pumping speed (w/o gas ballast) |
m³/h | 400 |
780 |
850 |
1660 |
480 |
910 |
1000 |
1940 |
Ultimate pressure w/o gas ballast |
mbar | 0,001 |
|||||||
Max. permissible outlet pressure (rel. to ambient) |
mbar | 200 |
|||||||
Max. permissible inlet pressure |
mbar | 1200 |
|||||||
Water vapor tolerance with gas ballast and inlet & outlet purge |
mbar | 20 |
|||||||
Water vapor capacity with gas ballast |
kg/h | 6,9 |
13,9 |
6,9 |
13,9 |
||||
Permissible ambient temperature |
°C | 0 to +40 °C |
|||||||
Purge gas consumption, inlet side |
slm | 2,5-5 |
5-10 |
2,5-5 |
5-10 |
||||
Purge gas consumption, motor side |
slm | 7,5-16 |
15-32 |
7,5-16 |
15-32 |
||||
Purge gas supply pressure |
bar (g) | 2-4 |
|||||||
Nominal motor power 50Hz / 60Hz |
kW | 9,4 |
16,5 |
9,4 |
17,5 |
||||
Dimensions (L x W H) |
mm | 1410 x 925 x 1503 |
1410 x 925 x 1772 |
1410 x 925 x 1896 |
1410 x 925 x 1503 |
1410 x 925 x 1772 |
1410 x 925 x 1896 |
||
Inlet / outlet connection |
DN63 / DN80 |
DN100 / DN80 |
DN100 / DN80 |
DN160 / DN80 |
DN63 / DN80 |
DN100 / DN80 |
DN100 / DN80 |
DN160 / DN80 |
Target applications for VDi:
- Heat Treatment
- Coating Applications
- Drying Applications