VARODRY VDi+ Banner

VARODRY VDi system

With integrated VAControl CAB for smart pump down

The VARODRY VDi are the perfect solution for smart pump down applications. These high-pumping speed versions are all equipped with our VAControl CAB for smart operation and energy saving functions. Profit from a powerful pump down to your set target pressure and benefit from significant energy savings as soon as target pressure is reached. The production configuration with purge, gas ballast and a self-draining design is perfectly suited for a wide range of applications. Intelligent software functions such as maintenance and service alerts or the set up of different user profiles guarantee best operation performance.

User advantages

Easy maintenance

Smart control

Energy efficient

Process capable

Low TCO

Performance driven

Energy Saver Kit for VD 400i+

Smart Pump Down with VDi:

  • More flexibility to adapt to your process needs
  •  Reduced process and maintenance costs 
  • Dry solution with higher pumping speed 
  • Reduced energy consumption to fulfill sustainability goals

Create more value with intelligent software functions:

  • Extra energy savings with the energy saver kit 
  • Significant cost of ownership reductions with intelligent energy saving procedures 
  • Allows to switch off one VARODRY to: 
    • Save on energy 
    • Save on running time to extended maintenance intervals 
  • Pump alternation for equal wear 
  • Pressure dependent and automatically controlled by the intelligent software 
  • erfectly suited for all heat treatment applications
Energy saving light bulb and tree growing on stacks of coins on nature background. Saving, accounting and financial concept.

Smart control with VAControl CAB:

  • Standardized products - ready-to-order! 
  • Intelligent pump systems with VAControl CAB 
  • One controller to manage all processes 
  • Pump data available from anywhere: 
    • Local, remote or cloud connectivity 
    • Data recording for best production quality 
  • Maintenance and service alerts for higher uptime 
  • Functions to enhance user experience: 
    • Starts / Stops of multiple pumps 
    • Pressure control 
    • Cloud communication via GENIUS 
  • Direct control via various devices 

 

…go digital today! 

Industry maintenance engineer woman dark skin wearing uniform and safety helmet under inspection and checking production process on factory station by tablet. Industry, Engineer, construction concept.

The Belt Tuner

A smart tool that helps you to adjust the belt of your VARODRY & NOVADRY

Easy Maintenance
The App is always ready and can be used no matter where you are

Smart Control
The App gives further insights like detailed instructions and provides data for further improvements

Cost Effective
As part of our NOVADRY & VARODRY concept, the Belt Tuner is free of charge

 

Technical Information
   

VARODRY VD 200i+

VARODRY VD 400i+

VARODRY VD 200i+

VARODRY VD 400i+

50 Hz

60 Hz

RUVAC  

WSU 501

WSU 1001

WSU 1001

WSU 2001

WSU 501

WSU 1001

WSU 1001

WSU 2001

Maximum pumping speed (w/o gas ballast)  

m³/h

400

780

850

1660

480

910

1000

1940

Ultimate pressure w/o gas ballast

mbar

0,001

Max. permissible outlet pressure (rel. to ambient)

mbar

200

Max. permissible inlet pressure

mbar

1200

Water vapor tolerance with gas ballast and inlet & outlet purge

mbar

20

Water vapor capacity with gas ballast

kg/h

6,9

13,9

6,9

13,9

Permissible ambient temperature

°C

0 to +40 °C

Purge gas consumption, inlet side

slm

2,5-5

5-10

2,5-5

5-10

Purge gas consumption, motor side

slm

7,5-16

15-32

7,5-16

15-32

Purge gas supply pressure

bar (g)

2-4

Nominal motor power 50Hz / 60Hz

kW

9,4

16,5

9,4

17,5

Dimensions (L x W H)

mm

1410 x 925 x 1503

1410 x 925 x 1772

1410 x 925 x 1896

1410 x 925 x 1503

1410 x 925 x 1772

1410 x 925 x 1896

Inlet / outlet connection

 

DN63 / DN80

DN100 / DN80

DN100 / DN80

DN160 / DN80

DN63 / DN80

DN100 / DN80

DN100 / DN80

DN160 / DN80

Documents
VARODRY VDi system

PDF    7.6 MB

language:
Download
The Belt Tuner

PDF    1.1 MB

language:
Download
Applications

Target applications for VDi:

  • Heat Treatment
  • Coating Applications
  • Drying Applications
   

VARODRY VD 200i+

VARODRY VD 400i+

VARODRY VD 200i+

VARODRY VD 400i+

50 Hz

60 Hz

RUVAC  

WSU 501

WSU 1001

WSU 1001

WSU 2001

WSU 501

WSU 1001

WSU 1001

WSU 2001

Maximum pumping speed (w/o gas ballast)  

m³/h

400

780

850

1660

480

910

1000

1940

Ultimate pressure w/o gas ballast

mbar

0,001

Max. permissible outlet pressure (rel. to ambient)

mbar

200

Max. permissible inlet pressure

mbar

1200

Water vapor tolerance with gas ballast and inlet & outlet purge

mbar

20

Water vapor capacity with gas ballast

kg/h

6,9

13,9

6,9

13,9

Permissible ambient temperature

°C

0 to +40 °C

Purge gas consumption, inlet side

slm

2,5-5

5-10

2,5-5

5-10

Purge gas consumption, motor side

slm

7,5-16

15-32

7,5-16

15-32

Purge gas supply pressure

bar (g)

2-4

Nominal motor power 50Hz / 60Hz

kW

9,4

16,5

9,4

17,5

Dimensions (L x W H)

mm

1410 x 925 x 1503

1410 x 925 x 1772

1410 x 925 x 1896

1410 x 925 x 1503

1410 x 925 x 1772

1410 x 925 x 1896

Inlet / outlet connection

 

DN63 / DN80

DN100 / DN80

DN100 / DN80

DN160 / DN80

DN63 / DN80

DN100 / DN80

DN100 / DN80

DN160 / DN80

VARODRY VDi system

PDF    7.6 MB

language:
Download
The Belt Tuner

PDF    1.1 MB

language:
Download

Target applications for VDi:

  • Heat Treatment
  • Coating Applications
  • Drying Applications
Contact Leybold

Let's talk

We focus on customer proximity. Contact us for all your questions.